Siemens S5/S7 Suite OPC+IO Server-PPI, Ethernet Master/Slave, AS511,3964 Driver

Price: US$795.00
Product#: 41233164
Availability: In Stock - Ships in 0 to 1 days.
Media: CD and/or Online Delivery

Product Summary

This communications driver product is intended for use with applications such as Wonderware InTouch, Wonderware System Platform, Wonderware Historian,OSIsoft PI,Intellution, Iconics, Indusoft, Cimplicity, WinCC, Visual Studio and many other applications that support OPC, FastDDE, SuiteLink, Intellution NIO, AdvanceDDE and DDE to connect them to Siemens S5 and S7 PLCs through a wide range of protocols. This suite contains 5 drivers covering a wide PLC range.

Read on for more information
Buy NOW
Buying Help
Demo
Screenshot
Ask The Expert
Print Page
Email Page
OPC Compliance Logo
This suite product provides incredible value because it includes 5 drivers that cover a range of connectivity options for Siemens S5 and S7 PLCs. Licensing is simple - a single license (pricing above) allows for unlimited tags and devices using any combination of the drivers listed below on a single PC.

For Wonderware users this product suite includes a native Suitelink Interface for quick easy connection to Wonderware InTouch 7.x through 10.x and beyond. Also works with Wonderware Industrial Application Server 2.x, System Platform 3.x, InSQL, and Historian using Suitelink or the proven, compliance tested OPC interfaces in TOP Server. Extensive free application notes and videos available to get you started fast.

Drivers Included in this Suite - click on a link below for details of each driver´s supported devices and capabilities:

S7-200/300/400 Ethernet Master - Devices Supported
  • Supports direct Ethernet connections to S7 CPU´s with Ethernet built in.
  • Supports Multiple Connection for each device
  • S7-200, S7-300 and S7-400 PLC families
  • NetLink supported on S7-300/S7-400 Models
  • Supports the CP-243 (S7-200), CP-343 (S7-300) and CP-443 (S7-400) TCP/IP Communications Cards in the PLC
  • Supports access on PC/PG/OP access ports
  • Memory Types Supported: I, E, Q, A, M, F, T, C, Z, and Data Block Access
  • Bit Level Access is supported
  • All data types are supported including string

The Siemens Ethernet device driver also supports the NetLink adapter cable. The NetLink adapter provides a low cost method of accessing either a Siemens S7-300 or S7-400 PLC via Ethernet without the need of the CP343 or CP443 communications card. NetLink offers a considerable savings for budget conscious projects.

S7-200 PPI and PPM Serial Driver - Devices Supported

S5 AS511 PG/Programming Port Driver - Devices Supported

In addition to a traditional connection to the PG port via an RS-232 to Current Loop convertor, this driver also supports Encapsulated Ethernet Mode which provides provide data exchange between OPC Clients and serial devices connected to an Ethernet serial port server device such as Lantronix, Digi, Comtrol, and others. Learn more about Ethernet Encapsulation.

This driver also supports telephone dialup modems.
  • AS511 Protocol using Current Loop - use of an RS-232/Current Loop convertor required - such as a B&B Electronics 232PCLR
  • S5 90U
  • S5 95U
  • S5 100U - 100U
  • S5 100U - 101
  • S5 100U - 103
  • S5 101U
  • S5 115U - 941
  • S5 115U - 942
  • S5 115U - 943
  • S5 115U - 944
  • S5 115U - 945
  • S5 135U -921
  • S5 135U - 922
  • S5 135U - 928
  • S5 155U - 946
  • S5 155U - 947
Data Formats Supported by AS511 Driver
  • I - Discrete Inputs
  • Q - DiscreteOutputs
  • F - Internal Memory
  • DB- Data Block Memory
  • C - Counter Current Value
  • T - Timer Current Value
  • Boolean - bit
  • Byte -8 bit
  • Word - unsigned 16 bit
  • Short - signed 16 bit
  • Long - signed 32 bit
  • DWord - unsigned 32 bit
  • Float - floating point, 32 bit

S5 3964/3964R Serial Driver - Devices Supported

This driver supports connections to Siemens S5 PLCs using the 3964?3964R protocol which is provided by a CP544 module inserted into the S5 PLC rack. Supported devices include:

S7-300 Ethernet Slave/Unsolicited Messages Driver - Features & Capabilities

Want to have your Siemens S7-300/400 PLCs talk to your HMI system instead of the other way around ? With this driver, it is all possible. When you install this driver on your PC and configure it, you can make it look like up to 256 "virtual" PLCs on your PC. You get a full memory map just like an S7-300 PLC.

Sample Architecture Using TOP Server S7 Ethernet Slave Driver
  • Uses S7 Messaging on Industrial Ethernet (ISO 8073 Class 0) over TCP/IP as defined in RFC1006
  • No special libraries or hardware required on the PC!
  • A standard Ethernet card is all that is needed.
  • Can appear as Rack 0-7 and CPU Slot 0-31
  • Up to 256 "virtual PCs"
  • The master S7 PLC talks to us with SFB14 - GET & SFB15 - PUT instructions in the master PLCs program
  • I, E, Q, A, F, M, memory supported with wide range of data types
  • Data Blocks (DB) supported with left byte, right byte, and bit access as well as full word access for variety of data types including float
  • Block Timers and Counters
  • Data Block Strings
  • Array Tag support


Operating System Support:

This communications driver is a member of the TOP Server family of products and shares a number of powerful features in common with all of the products in the TOP Server family. The TOP Server family represents the latest in client-server communications technology for connecting HMI, Historian, Database, and other applications to plant floor equipment.

Broad OPC Support
The TOP Server implements both the OPC 1.0a, 2.0, and 3.0 Data Access Specifications giving you the choice of the widest range of OPC client applications. The TOP Server is continuously tested with the most popular OPC client applications on the market to insure ease of use, integration, and reliability, including popular names as Wonderware, Siemens WinCC, Intellution, Iconics, Cimplicity, RSView and more.

Full Support for Wonderware FastDDE and Suitelink
The TOP Server's support of Wonderware Corporation's FastDDE and SuiteLink simplifies the task of connecting the server with FactorySuite applications such as InTouch. By using the Wonderware connectivity toolkit, our TOP Server can simultaneously provide OPC and FastDDE/SuiteLink connectivity to address your communications needs. With built-in support of these Client/Server technologies, the TOP Server allows you to quickly access device data without the need to use an intermediary software bridge (i.e. OPC Link) as is done when using a strictly OPC only communications server. For Wonderware users the familiar look and feel of FastDDE/SuiteLink tag database setup is maintained. Backwards compatibility for legacy DDE is also supported.

Intellution NIO native interface supported - no OPC Power Tool needed!
Direct connection to the iFix Process Database allows you to skip the OPC Power Tool. Enabling the iFix PDB interface on the TOP Server Tools->Options menus causes the TOP server to appear as a native Intellution driver named "IDS". Never before has connecting TOP Server to Intellution iFix been easier.

Legacy Support for DDE
While OPC has become the defacto format of choice for communications drivers in the automation market, we realize that not everyone can replace their client software with the latest OPC client versions. For this reason, the TOP Server is one of the few OPC servers on the market to also simulataneously support Wonderware's FastDDE and Suitelink interfaces, Rockwell's AdvanceDDE and Microsoft's standard DDE interfaces for connecting the TOP Server to your client application. With the TOP Server you can connect to your legacy DDE clients today and move smoothly to the world of OPC when you are ready and not have to worry about replacing or re-configuring the communications driver connecting you to your production machinery.

Other Key Features in the TOP Server

Runtime Configuration Changes A very unique feature to this product is the ability to change your configuration while the server is running and has clients connected. The connected client application has access to a group of system tags that allow the client to request the TOP Server to change which network card it is using, change which com port it is using, change the IP address of the target device, change the Device ID of a target serial device, change serial communications parameters including RTS line control and flow control, and change diagnostic settings. This capability enables you to do Redundancy at the network media, serial connection media, and device levels -- your client application makes the determination that the target device is no longer operable by any means you choose, including monitoring our _Error system tag for communications errors, and when the client application wants the TOP Server to switch, it simply writes to the appropriate system level tag to change network connection, com port, or target device ID/IP address. Redundancy is just one of the powerful types of complex applications that these runtime-configurable features can enable.

Import Tag Databases from KEPServer Your existing KEPServer version 3.x/4.x tag databases are readable by the new TOP Server so you can migrate your existing application seamlessly to the TOP Server.

Online Full Time The TOP Server allows you to make changes to your tag database configuration at any time. In older versions, you could be online, but not add tags, or be offline to add tags but not read data. With the TOP Server you make changes when you need to, on the fly.

User Management With powerful features such as online changes, you want to make sure you manage who is allowed to make what changes. The User Manager in the TOP Server lets you define what different people can change and update in the servers' configuration.

Tag Management You want to organize your tag database around your process. With the TOP Server we've taken full advantage of OPC grouping capabilities to let you segregate and organize your tags the way you want them. Drag and Drop configuration lets you quickly move, add, copy large numbers of tags quickly and easily. CSV (Ascii comma-delimited) format import and export lets you bring in your tags from an Excel worksheet or export them, edit them in bulk and bring them back in.

Tag Scaling Display your data in units that are meaningful to you. The TOP Server supports Linear and Square Root tag scaling. You define the display format and the engineering units display string to meet your needs.

Diagnostics The TOP Server family of communications products provide real time diagnostics on all tag read/write operations that can be viewed in your OPC client to keep tabs on what is going on in the server. For those tough to debug communications problems, you can turn on our diagnostic window and capture protocol packets off to disk to find out what is really happening between the computer and the hardware device.

Other Powerful Features in the TOP Server include:

  • Tag Browsing
  • Modem support built in for serial drivers
  • Extensive help files and examples of how to use the TOP Server with popular OPC clients
  • Visual Basic OPC client sample code
  • 32-bit high performance multi-threaded drivers
  • Auto-Start for unattended operation
  • Works with any OPC client or DDE, AdvancedDDE client application
  • Works with Wonderware's FastDDE and SuiteLink interfaces

Siemens S5/S7 Suite OPC+IO Server-PPI, Ethernet Master/Slave, AS511,3964 Driver
Price: US$795.00
Product#: 41233164
Availability: In Stock - Ships in 0 to 1 days.
Media: CD and/or Online Delivery
Buy NOW
Buying Help

 | HOME | PRODUCTS & SERVICES | PRODUCT SUPPORT | ABOUT US | ACCOUNT SERVICES | SEARCH

P: 1-888-665-3678 (US-Sales) or 704-849-2773 (Support & International), F: 704-849-6388
148A East Charles Street, Matthews, North Carolina, USA 28105
Copyright Software Toolbox, Inc., 1996-2008, All Rights Reserved Worldwide.